Form correction and volume increase. Reconstruction after mastectomy.
Form stable breast implant on carbon-chain copolymer, possessing high mechanical strength, elasticity, resistance to biochemical and hydrolytic disintegration.
It is used in esthetic surgery for breast form correction and volume increase, as well as in reconstructive-restorative operations after breast extirpation (complete or partial).
NUBIPLANT implant advantages
Implant is biologically and physiologically compatible with human body tissues
Implant by its consistency and elasticity is equivalent to breast tissues
Implant has rapid relaxation, which excludes "plasticine" effect and visual presence signs
Implant is monolithic structure, composed of continuous cross-linked net, penetrating the whole volume, which absolutely excludes "exfoliation", "leaking", primary components diffusion
Implant has external highly-structured barrier layer, which has covering properties
Implant has basis texturized surface, it adjoins better chest wall, which excludes its abnormal mobility
Implant has high elasticity, its relative lengthening is over 500 %
Implant has high cohesiveness, which secures its geometric stability.
Implant is resistant to radiological influence
Clinical effect from NUBIPLANT implants use
It secures more natural and proportional breast form
It is possible to obtain with it breast anatomical form without using drop-shape models
It secures foreseeable prolonged effect
Thin-walled connective tissue capsule is formed without fibrosis signs and in-growth into implant that significantly decreases complications frequency
Implant is resistant to irradiation up to 40 Gr, which allows applying, if needed, complex therapy immediately after implantation
Implant has high operating performance characteristics, for example, resistance to mechanical damages
Implant does not resorb
Indications:
Breasts volume increase
Breasts form correction
Breast asymmetry elimination
Chest deformation correction
Breast reconstruction after subcutaneous mastectomy or radical mastectomy
Need for implant replacement
Contraindications:
Mastitis, abscess
Acute and relapsing infectious diseases
Allergic conditions and diseases
Psychic instability in patients
Pre-clinical trials:
National Academy of Sciences of Ukraine
L.I. Medved Institute of Ecohygiene and Toxicology
Clinical trials:
P.L. Shupik National Medical Academy of Post-Graduate Education
National Institute of Cancer
Kyiv City Mammological Center
"Feofania" Clinical Hospital
Bioethics expertise:
Ethics Committee of P.L. Shupik National Medical Academy of Post-Graduate Education
Ethics Committee of "Feofania" Clinical Hospital
NUВІPLANT™ breast implants with round basis
Average profile High profile
Implant code |
Volume (cm3) |
D (mm) |
Projection (mm) |
Implant code |
Volume (cm3) |
D (mm) |
Projection (mm) |
FS-17075 |
170 |
97 |
31 |
FS-17080 |
170 |
100 |
32 |
FS-18590 |
185 |
100 |
32 |
FS-18595 |
185 |
103 |
33 |
FS-21000 |
210 |
104 |
35 |
FS-21020 |
220 |
105 |
36 |
FS-23040 |
230 |
106 |
36 |
FS-23045 |
230 |
117 |
37 |
FS-25060 |
25) |
108 |
38 |
FS-25065 |
250 |
110 |
41 |
FS-27000 |
270 |
110 |
40 |
FS-27075 |
270 |
114 |
41 |
FS-29080 |
290 |
114 |
41 |
FS-29030 |
290 |
117 |
42 |
FS-31020 |
310 |
117 |
42 |
FS-31030 |
310 |
119 |
43 |
FS-34050 |
240 |
119 |
43 |
FS-34060 |
340 |
120 |
44 |
FS-37080 |
370 |
123 |
44 |
FS-37090 |
370 |
125 |
45 |
FS-40000 |
400 |
125 |
45 |
FS-40010 |
400 |
130 |
46 |
FS-42000 |
420 |
130 |
46 |
FS-44030 |
430 |
140 |
48 |
FS-44050 |
440 |
135 |
47 |
FS-44060 |
440 |
145 |
50 |
|