Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/nubiplan/eng.nubiplant.ua/engine/classes/templates.class.php on line 243 Nubiplant > Print version > Nubiplant – form-stable breast implants
Nubiplant / Nubiplant – form-stable breast implants

Nubiplant – form-stable breast implants

Form correction and volume increase. Reconstruction after mastectomy.

Form stable breast implant on carbon-chain copolymer, possessing high mechanical strength, elasticity, resistance to biochemical and hydrolytic disintegration.

It is used in esthetic surgery for breast form correction and volume increase, as well as in reconstructive-restorative operations after breast extirpation (complete or partial).

NUBIPLANT implant advantages

Implant is biologically and physiologically compatible with human body tissues
Implant by its consistency and elasticity is equivalent to breast tissues
Implant has rapid relaxation, which excludes "plasticine" effect and visual presence signs
Implant is monolithic structure, composed of continuous cross-linked net, penetrating the whole volume, which absolutely excludes "exfoliation", "leaking", primary components diffusion
Implant has external highly-structured barrier layer, which has covering properties
Implant has basis texturized surface, it adjoins better chest wall, which excludes its abnormal mobility
Implant has high elasticity, its relative lengthening is over 500 %
Implant has high cohesiveness, which secures its geometric stability.
Implant is resistant to radiological influence

Clinical effect from NUBIPLANT implants use

It secures more natural and proportional breast form
It is possible to obtain with it breast anatomical form without using drop-shape models
It secures foreseeable prolonged effect
Thin-walled connective tissue capsule is formed without fibrosis signs and in-growth into implant that significantly decreases complications frequency
Implant is resistant to irradiation up to 40 Gr, which allows applying, if needed, complex therapy immediately after implantation
Implant has high operating performance characteristics, for example, resistance to mechanical damages
Implant does not resorb

Indications:

Breasts volume increase
Breasts form correction
Breast asymmetry elimination
Chest deformation correction
Breast reconstruction after subcutaneous mastectomy or radical mastectomy
Need for implant replacement

Contraindications:

Mastitis, abscess
Acute and relapsing infectious diseases
Allergic conditions and diseases
Psychic instability in patients

Pre-clinical trials:

National Academy of Sciences of Ukraine
L.I. Medved Institute of Ecohygiene and Toxicology

Clinical trials:

P.L. Shupik National Medical Academy of Post-Graduate Education
National Institute of Cancer
Kyiv City Mammological Center
"Feofania" Clinical Hospital

 

Bioethics expertise:

Ethics Committee of P.L. Shupik National Medical Academy of Post-Graduate Education
Ethics Committee of "Feofania" Clinical Hospital

 

NUВІPLANT™ breast implants with round basis

 

Average profile                                                         High profile


Implant code

Volume (cm3)

D (mm)

Projection (mm)

Implant code

Volume (cm3)

D (mm)

Projection (mm)

FS-17075

170

97

31

FS-17080

170

100

32

FS-18590

185

100

32

FS-18595

185

103

33

FS-21000

210

104

35

FS-21020

220

105

36

FS-23040

230

106

36

FS-23045

230

117

37

FS-25060

25)

108

38

FS-25065

250

110

41

FS-27000

270

110

40

FS-27075

270

114

41

FS-29080

290

114

41

FS-29030

290

117

42

FS-31020

310

117

42

FS-31030

310

119

43

FS-34050

240

119

43

FS-34060

340

120

44

FS-37080

370

123

44

FS-37090

370

125

45

FS-40000

400

125

45

FS-40010

400

130

46

FS-42000

420

130

46

FS-44030

430

140

48

FS-44050

440

135

47

FS-44060

440

145

50

7-02-2015, 11:13
Back